2-2-15-10-proverka-raspredvala.html
2.2.15.10. Cam-shaft checkEstablish necks No. 1 and cam-shaft No. 5 on prisms.
|
Fig. 2.152. Measurement of palpation of a cam-shaft
|
If palpation does not correspond to norm, replace a cam-shaft.
Maximum palpation: 0,03 mm.
|
Fig. 2.153. Measurement of height of a contour of a cam
|
Measure height of a contour of a cam in two points, as is shown in drawing 2.153.
If the height does not correspond to norm, replace a cam-shaft.
Neck No. 1.
Standard height of a cam-shaft of L8:
Admission – 40,79 mm;
Release – 41,08 mm.
Cam-shaft of LF, L3:
Admission – 42,12 mm;
Release – 41,08 mm.
With the mechanism of change of phases of a gazoraspredeleniye:
Admission – 42,44 mm;
Release – 41,18 mm.
Neck No. 5
Standard height of a cam-shaft of L8:
Admission – 40,692 mm;
Release – 40,982 mm.
Cam-shaft of LF, L3:
Admission – 42,022 mm;
Release – 40,982 mm.
With the mechanism of change of phases of a gazoraspredeleniye:
Admission – 42,342 mm;
Release – 41,082 mm.
|
|