7.2.1.6. Check of completely charged battery room of the batteryEstablish on the ampermeter (with a limit of measurement 0–5 мА and 0–5 And) the highest limit of measurement. Turn on the ampermeter between a minus conclusion of the battery and a weight cable. The Plusovy wire of the ampermeter connect to a plusovy conclusion of the battery, a minus wire of the ampermeter – to a minus conclusion of the battery.
Switch off everything consumers of the electric power, close all doors and a luggage carrier, switch off a plafond of illumination of a motor compartment.
Switch a limit of measurement of the ampermeter towards reduction until there will be any indications (admissible value makes 1–3 мА). Taking out one after another safety locks from the block of safety locks, disconnect consistently all electric chains. If at disconnection of one of chains of the indication will fall to 0, in this chain it is necessary to look for a malfunction source. Possible malfunctions: the korrozirovavshy or polluted contacts of the electric sockets, the ground wires, internal short circuit in electric equipment elements.
If in the chains of malfunction protected by safety locks it is not revealed, disconnect wires from unprotected by safety locks of devices: generator, starter, elements of system of ignition.
If at shutdown of one of unprotected chains of the indication of the ampermeter will fall to 0, repair or replace the corresponding element. At leakage of a current in a starter or ignition system always check (according to the scheme) the ignition and starter switch.
|