Mazda 6 since 2002
1. Operation and car maintenance
2. Engine
2.1. General description of new engines of the L8, LF and L3 models
2.2. Mechanical part of engines
2.3. Appendix 1
2.4. Appendix 2
2.5. Appendix 3
2.5.1. Control system
2.5.2. Principle of work and purpose of some components of a control system
2.5.3. Codes of malfunctions
2.5.3.1. Codes of malfunctions
2.5.3.2. Synchronization of provision of a cam-shaft
2.5.3.3. Heater of the sensor of concentration of oxygen
2.5.3.4. The pressure sensor in an inlet collector
2.5.3.5. The pressure sensor in an inlet collector
2.5.3.6. The air temperature sensor on an admission (air temperature on an admission)
2.5.3.7. Sensor of provision of a butterfly valve
2.5.3.8. Fuel system
2.5.3.9. Monitoring of the admission of ignition
2.5.3.10. Detonation sensor
2.5.3.11. The valve of a retsirkulyatsiya of the fulfilled gases
2.5.3.12. Neutralization system
2.5.3.13. Electromagnetic valve of a purge
2.5.3.14. Control system of fans of system of cooling
2.5.3.15. Neutral switch
2.5.3.16. The electromagnetic valve of system of an admission with variable characteristics (VAD)
2.5.3.17. PCM block
2.5.3.18. Control system of air hashing
2.5.3.19. Sensor of barometric pressure
2.5.3.20. Generator
3. Transmission
4. Running gear
5. Steering mechanism
6. Brake system
7. Onboard electric equipment
8. Body
 







2-5-3-5-datchik-davleniya-vo-vpusknom-kollektore.html

2.5.3.5. The pressure sensor in an inlet collector

Low level of an entrance signal of a chain of the sensor of pressure of air in an inlet collector (P0107)
The PCM block supervises entrance tension of the sensor of pressure in an inlet collector when air temperature on an admission is higher than 10 °C. If entrance tension in a conclusion 1J the PCM block – below 0,1 In, the PCM block decides that the chain of the sensor of pressure in an inlet collector has malfunction.

High level of an entrance signal of a chain of the sensor of pressure of air in an inlet collector (P0108)
The PCM block supervises entrance tension of the sensor of pressure in an inlet collector when air temperature on an admission is higher than 10 °C. If entrance tension in a conclusion 1J the PCM block – above 4,9 In, the PCM block decides that the chain of the sensor of pressure in an inlet collector has malfunction.

«previous page
2.5.3.4. The pressure sensor in an inlet collector
following page»