2-3-3-2-proverka-proizvoditelnosti.html
2.3.3.2. Productivity check
NOTE
If at your order there is no special tester of fuel nozzles, execute «The test of leakage of fuel» to check serviceability of a fuel nozzle.
|
Disconnect a negative wire of the storage battery.
Remove fuel nozzles.
Connect a fuel nozzle to the tester of fuel nozzles.
Measure volume of the fuel injected each fuel nozzle, using the graduated container. If the size of leak exceeds norm, replace a fuel nozzle.
Volume of injected fuel:
L3: 61–71 ml / 15 with;
LF: 53–69 ml / 15 with;
L8: 48–63 ml / 15 pages.
Turn the ignition key in the situation LOCK and remove a crossing point.
Establish nozzles into place.
|